2019 Cycle
Building Type
Multifamily
Related Measures
-
Drain Water Heat Recovery
The drain water heat recovery (DWHR) measure is completely new in the California Building Energy Efficiency Standards, and saves water heating energy expended during showering. This measure applies to new construction of low-rise residential buildings. DWHR is likely cost-effective in some high-rise ... -
Compact Hot Water Distribution Design
The Compact Hot Water Distribution proposal is intended to provide builders a compliance option credit for designing residential buildings with hot water use fixtures located close to the water heater, saving both energy and water. A compliance option represents a voluntary measure available to builders ... -
Demand Response Language Clean-Up
The objective of this code change proposal is to clean up and clarify the existing demand response (DR) requirements so that all sections of the standards use consistent terminology and approach. The goal is to improve comprehension of and compliance with the existing requirements ... -
Residential Ventilation & Indoor Air Quality
The most significant proposed change to the 2016 Title 24, Part 6 Residential Standards is the adoption of the 2016 version of ASHRAE Standard 62.2, Ventilation and Acceptable Indoor Air Quality in Low-Rise Residential Buildings. The 2016 ASHRAE Standard 62.2 version replaces the California version of ASHRAE Standard 62.2-2010 (which includes Addenda b, c, e, g, h, i, j, l, and n) that was adopted by the 2016 Title 24 Building Energy Efficiency Standards (BEES) ... -
Residential Quality Insulation Installation (QII)
Under the 2013 and 2016 code, a compliance credit is awarded for installations that perform Quality Insulation Installation (QII). The Standard Design assumes that builders are not performing QII and wall insulation values are modeled at 70 percent of the R-value of the installed insulation, with attic ... -
High Performance Windows and Doors
This measure improves the performance of fenestration products—windows and doors—in the low-rise residential buildings by lowering the required U-factors for both products, and for windows by adjusting the solar heat gain coefficients (SHGC) by Climate Zone to further reduce energy use ... -
High Performance Attics
The proposed residential high performance attic (HPA) measure increases the prescriptive performance of the residential envelope in certain climates, primarily reducing the cooling season heat transfer through the roof deck, contributing to lower heating, ventilation, and air conditioning (HVAC) loads ... -
High Performance Walls
The proposed residential high performance walls measure increases the prescriptive performance of the residential envelope in certain climates, reducing the amount of heat transfer through walls and subsequently reducing heating, ventilation, and air conditioning (HVAC) loads ... -
Residential Quality HVAC
Mandatory fan efficacy requirement: Reduce the maximum air handling unit fan efficacy currently required under Title 24 Part 6, 150.0(m)13 from 0.58 watts per cubic feet per minute (W/cfm) to 0.45 W/cfm ...